PR and Marketing

Daria Getsman
`

Daria Getsman

Head of External Relations

getsman@triolcorp.com

+17134890309

Variable Speed Drive Triol AK06 narrows Harmonic Distortion down

05/10/2016

Triol AK06 VSD offers a broad range of control modes, features, options, and packaging, for use in factory automation processes and industrial OEM machines. Triol AK06 VSD with active harmonic filter (AHF) comes as an optimal solution for the efficient operation of oil companies.

Such elaboration is useful for petroleum production; it’s intended to reduce harmonic distortions in the network caused by work of 6-12-pulse rectifiers of VSD. Triol AK06 VSD with AHF includes the full functional management of ESP, compatible with different submersible motors (Induction, PMM, Linear), it is designed to protect downhole installation of the ESP series from 80 to 1700 kVA. High-powered semiconducting converters have negative effect on the main supply in connection with a non-sinusoidal current consumption. It distorts the form of the current consumption to 40%, while the power factor decreases to 0,8%. This leads to the reactive current consumption and excessive heating of supply conductors. Integrated input and output filters allow you to have a quick start of work installation as well as to provide high-quality of supplying voltage for network. A period of engine service reaches the same values as when runs directly from the mains. Active filtration generates ac signal that is back of harmonic distortion.

It affords to get sinusoidal current consumption and eliminate additional losses in heating the supply conductors. As a result, current consumption is obtained a form close to sinusoidal with harmonic reducing from 30% to 5%. A tendency like this is fully compliant with IEEE519 standard. Triol Variable Speed Drives have defined capability to withstand voltage and current waveform distortion. The latest IEEE standard 519 defines harmonic distortion limits acceptable on the input side to the AC power system.

Harmonics may be greatly magnified by power factor correction capacitors. Supply system inductance can resonate with the capacitors at some harmonic frequency, causing large currents and voltages to develop. This may damage equipment. In addition, since the impedance of a capacitor decreases with increasing frequency, capacitors tend to act as sinks for higher-order harmonics.

Triol AK06 VSD is space-saving and high-powered equipment. It provides uninterrupted control algorithms on the set of asynchronous and brushless motors, minimizes the distortion of the mains supply and ensures minimum wear of downhole equipment. Using this installation is useful for oil companies where the generator power should be full used either reduced losses from current harmonics and reactive currents.

Triol AK06 VSD with AHF is a new solution for efficient protection of the whole system from grid outage by reducing a network load.

News
The SPE Symposium, the…

25/04/2019

The petroleum industry exists to supply a wide range of essential products to a variety of…

LESP – the Future…

27/12/2018

Triol Corporation provides not only solutions for oil production, but the future image of oilfield…

Discounts & Convenience: TriolCorp…

10/12/2018

TriolCorp has launched new Internet store of variable speed drives. Now you can buy customized…

Manama Oil Show Highlights:…

07/12/2018

Triol Corporation is a well-known leader in manufacturing equipment for artificial lift serving the needs…

New AT24 Series: Triol…

22/11/2018

Must-Have Solution Variable frequency drive application field is so broad that it is hard to…

Oil News: Triol to…

13/11/2018

Currently, intelligent lift is one of the most solicited trends in oil production, due to…

PBIOS 2018 Overview: Triol…

01/11/2018

Permian Basin has a rich history connected to oilfield development. Recently, the region hosted a…