Triol AK06 VSD offers a broad range of control modes, features, options, and packaging, for use in factory automation processes and industrial OEM machines. Triol AK06 VSD with active harmonic filter (AHF) comes as an optimal solution for the efficient operation of oil companies.

Such elaboration is useful for petroleum production; it’s intended to reduce harmonic distortions in the network caused by work of 6-12-pulse rectifiers of VSD. Triol AK06 VSD with AHF includes the full functional management of ESP, compatible with different submersible motors (Induction, PMM, Linear), it is designed to protect downhole installation of the ESP series from 80 to 1700 kVA. High-powered semiconducting converters have negative effect on the main supply in connection with a non-sinusoidal current consumption. It distorts the form of the current consumption to 40%, while the power factor decreases to 0,8%. This leads to the reactive current consumption and excessive heating of supply conductors. Integrated input and output filters allow you to have a quick start of work installation as well as to provide high-quality of supplying voltage for network. A period of engine service reaches the same values as when runs directly from the mains. Active filtration generates ac signal that is back of harmonic distortion.

It affords to get sinusoidal current consumption and eliminate additional losses in heating the supply conductors. As a result, current consumption is obtained a form close to sinusoidal with harmonic reducing from 30% to 5%. A tendency like this is fully compliant with IEEE519 standard. Triol Variable Speed Drives have defined capability to withstand voltage and current waveform distortion. The latest IEEE standard 519 defines harmonic distortion limits acceptable on the input side to the AC power system.

Harmonics may be greatly magnified by power factor correction capacitors. Supply system inductance can resonate with the capacitors at some harmonic frequency, causing large currents and voltages to develop. This may damage equipment. In addition, since the impedance of a capacitor decreases with increasing frequency, capacitors tend to act as sinks for higher-order harmonics.

Triol AK06 VSD is space-saving and high-powered equipment. It provides uninterrupted control algorithms on the set of asynchronous and brushless motors, minimizes the distortion of the mains supply and ensures minimum wear of downhole equipment. Using this installation is useful for oil companies where the generator power should be full used either reduced losses from current harmonics and reactive currents.

Triol AK06 VSD with AHF is a new solution for efficient protection of the whole system from grid outage by reducing a network load.

News
Vesting ownership of the…

01/20/2020

Harmonic distortion in three-phase circuits is a well-known common problem that leads to a decrease…

Triol AT27 VFD Vacuum…

01/13/2020

Multilevel frequency drives conquered the industrial market a long time ago. With all the modern…

Triol Online Store: Purchase…

01/08/2020

Dear Friends, Customers, and Partners! New Year is a magical time when every wish can…

Downhole Measuring System Triol…

01/06/2020

We never stop advancing our solutions, walking side by side with modern technologies. Downhole Measuring…

Merry Christmas and Happy…

12/25/2019

This year turned out to be really productive and eventful for Triol Corporation. As we…

Triol EP01 New Copyright…

12/16/2019

Triol vast experience in the field of electrical equipment for oil and general allows developing…

Triol Online Store: find…

12/10/2019

Living in the time of modern technologies, we're constantly evolving, advancing the ways to provide…

General comments:

Leave a Reply

Comments from Facebook: